0Function level 1 2
3-20
3-5 Basic Operation
3-5-1 Function Level Selection Setting (SET Mode)
H Function Level Selection Setting and Checking
Check if the function level is set to function level 1 (basic operation/monitor only). Change to function
level 1 (basic operation/monitor only) if set to a different level.
Function
No.
Parameter
No.
Function Setting
range
Details
U (u) 1 Function
level
selection
0 to 2 0: Function level 0 (monitor only)
1: Function level 1 (basic operation/monitor
only) (factory setting)
2: Function level 2 (all functions)
D Procedure
Set the function level selection to “1” (function level 1).
Operation Display Explanation
If the Cam Positioner power is turned ON while in RUN
mode, the display will appear as shown to the left.
Bank/Function: Displays the bank number specified
by the bank selection input (banks 1 to 3).
Cam/Parameter: (Clear)
SPEED/ON angle display: Displays the Resolver
speed (r/min).
POSITION/OFF: Displays the present angle.
Use the mode selection switch to change to SET
mode.
BANK/
FUN
Keep pressing the Bank/Function Key until “U” appears
on the display.
Note The display will change from
12....8AtU1..
SET
Press the Set Key to allow settings to be made.
Cam/Parameter number display: “1”
SPEED/ON angle display: Flashes current setting
If the setting is not on “1,” use the Up or Down Key to
change to “1” (function level 1).
0: Function level 0
1: Function level 1
2: Function level 2
Operation Chapter 3