3-21
Operation ExplanationDisplay
SET
Press the Set Key to confirm the settings.
The setting will stop flashing for approximately
1 second and then resume flashing.
Note When a setting is flashing, the Up and Down
Keys are enabled and the setting may be
changed.
BANK/
FUN
Press the Bank/Function Key.
The display will return to only the function number that
appears.
Turn OFF the power supply. (The settings will now be
enabled.)
Note 1. The functions are enabled once the power has been turned OFF and then ON again.
Note 2. The display will change as shown below when the Bank/Function Key is pressed repeatedly
to set the function number.
Function level 0: 12345678U1etc.
Function level 1: 12345678AtU1etc.
Function level 2: 12345678AbCdFHPtU1etc.
If the resolution selection (explained in the next section) is set to “1” (720 divisions/rotation),
5678” will not be displayed.
3-5-2 Initial Settings
Only the rotation direction (CW/CCW selection switch) and resolution setting (SET
mode) are changed at function level 1.
H Rotation Direction Selection Setting
The CW/CCW setting switch is used to change the direction of rotation.
CW/CCW setting switch
Set the direction of increasing angles to “CW” for clockwise direction when viewed from the Resolver
axis, and “CCW” for counterclockwise direction (as shown in the following diagram).
Note These settings will be enabled by turning the power supply OFF and then ON again.
Operation Chapter 3