EasyManua.ls Logo

Omron 3F88L-160 - Page 78

Omron 3F88L-160
238 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function level 1 2
3-22
D Relationship between Resolver Rotation Direction and Rotation Direction Selection
Increasing angles Increasing angles
Direction of increasing angles when
setting switch is set to “CW.”
Direction of increasing angles when
setting switch is set to “CCW.”
H Resolution Selection (SET Mode)
Select a resolution of either 360 or 720 (divisions/rotation).
D Resolution Selection Details
Function
No.
Parameter
No.
Function Setting
range
Details
A (a) 1 Resolution
selection
0, 1 0: 360 divisions/rotation (factory setting)
1: 720 divisions/rotation
D Functions and Performances Affected by Resolution Setting
Function or Characteristic 360 resolution 720 resolution
Angle setting and display units 1° is set and displayed as “1.” 0.5° is set and displayed as “1.”
Permissible Resolver speed 1,600 r/min 800 r/min
No. of cam program steps 180 max. 360 max.
Number of banks 8 4
Note For example, to set the ON angle at 90°, the setting is “90” for a 360 resolution and “180” for a 720
resolution.