1-11
1-5 Operation Procedure
1-5-1 Before Operation
H Basic Use
The procedure for using the Cam Positioner at function level 1 (basic operation/monitor only) is out-
lined below.
Procedure Contents Reference
section
Installation Install the Cam Positioner according to the installation
environment conditions.
2-2
Wiring Connect the wiring for the power supply, Resolver, and
peripheral devices.
2-3
Power ON Before the power is turned ON:
Check that the wires and connectors for the Resolver and
peripheral devices have been connected properly.
Check that the Resolver and the machinery are not con-
nected.
After the power is turned ON:
Check that there are no error codes displayed (E–**).
Set the mode selection switch to RUN and check that the
number of revolutions and the present angle display changes
when the Resolver axis is rotated by hand.
Function level selection Select function level 1 (basic operation/monitor only). 3-5-1
Initial settings Set the resolution (SET mode) and rotation direction
(CW/CCW) to suit the application.
3-5-2
Power resetting (OFF to
ON)
Turn ON the power to enable the set parameters.
Creation and confirmation
of cam programs
Create and check cam programs (PRGM mode).
Check the number of programs (SET mode).
3-5-3
Connection between
Resolver and machinery
Turn OFF the power and connect the Resolver and the
machinery.
3-5-4
Execution of origin
compensation
Turn ON the power and execute origin compensation (use
the ADJ switch in SET mode).
3-5-5
Operation/monitoring Change to RUN mode and check the operation of the
machinery and monitor the I/O status. Correct the cam
program if required (PRGM mode).
3-5-6
Function level selection If required, set to function level 0 (monitor only) to prevent
faulty operation.
3-4
Note This procedure is applicable when only the basic functions (function level 1) are used. In the
cases outlined below, the applied functions (function level 2) must be used. (Refer to 3-6 Applied
Functions.)
S When setting origin compensation values, using backlash compensation, advance angle com-
pensation, and other compensation functions.
S When executing a trial or compensation operation.