3-40
3-5-7 I/O Monitor Function (RUN Mode)
The 3F88L-160/162 Cam Positioners have the following monitor functions in RUN
mode. If the system does not perform properly at start up, use this monitor function first
and check the I/O status.
S Resolver speed and present angle
S Error display
S Cam output status
S Control I/O signal status
H Resolver Speed and Present Angle Monitoring (RUN Mode)
If the Cam Positioner is set to RUN mode, the Resolver speed (r/min) will be displayed in the SPEED/
ON display and the present angle (in 1° units for 360 resolution and 0.5° units for 720 resolution) is dis-
played in the POSITION/OFF display.
Bank No. being executed
“ru”: Shows that START input is ON in RUN mode.
Present angle
Resolver speed
H Error Display
If an error is generated, an error code (E–**) will appear in the SPEED/ON display.
If an error has been generated, refer to Chapter 5 Operation for countermeasures.
Error code
Operation Chapter 3