6-2
6-1 Cam Positioner Specifications
H General Specifications
Model 3F88L-160 3F88L-162
Power supply voltage 100 to 240 V AC, 50/60 Hz
Allowable power
supply voltage
85 to 264 V AC
Current consumption 18 VA max.
Inrush current 40 A/10 ms max.
I/O power supply 24 V DC/145 mA
Allowable I/O power
supply voltage
20.4 to 26.4 V DC
Insulation resistance 20 M min. between all AC power supply external terminals and the protective
ground terminal (500 V) (see note)
Dielectric strength 2,300 V AC, 50/60 Hz for 1 minute between all AC power supply external terminals
and the protective ground terminal (leakage current of 10 mA max.) (see note)
Noise immunity 1,500 Vp-p, pulse width of 0.1 to 1 µs, 1-ns rising pulse (noise simulator)
Vibration resistance 10 to 57 Hz, 0.075-mm single amplitude
57 to 150 Hz with an acceleration of 9.8 m/s
2
for 80 minutes each in X, Y, and Z
directions (8 minutes x 10 times = 80 minutes)
Shock resistance 147 m/s
2
, 3 times each in X, Y, and Z directions
Ambient operating
temperature
0 to 55°C
Ambient operating
humidity
10 to 90% (with no condensation)
Ambient operating
environment
No corrosive gases
Ambient storage
temperature
–20 to 75°C
Terminal screws Power supply input section: M3.5 screws
Control I/O section: M3 screws
Momentary power
interruption detection
time
Power interruptions of 15 ms or less are not detected.
External dimensions 110 × 100 × 82.5 mm (W × H × D)
Weight 1 kg max.
Degree of protection Panel-mounting
Mounting method M4 screws (2 points) or DIN track mounting
Note Disconnect the functional ground terminal from the protective ground terminal when performing
insulation resistance or withstand voltage tests