3-14
3-4 Selecting Function Levels
Three function levels are available to limit 3F88L-160/162 Cam Positioner functions by
setting the function level selection (Function No. U).
Limiting the Cam Positioner functions protects it from being incorrectly set or operated
by the user.
S Function Level 0 (Monitor Only)
Cam output and monitoring are enabled.
Cam program writing and parameter setting cannot be made.
Function level 0 is designed to prevent inadvertent changes to the cam program or
parameters.
Functions for which the settings have already been completed are enabled and may
be used at this level.
S Function Level 1 (Basic Operation/Monitor Only) (Factory Setting)
In addition to the functions available at function level 0, cam programs may be
edited.
This function level is used for basic operation.
S Function Level 2 (All Functions)
All Cam Positioner functions are enabled.
This function level is for using applied functions.
It is recommended, therefore, that cam programs be created and parameters set at level
2 (or level 1) first and then the 3F88L-160/162 Cam Positioner be used at level 0 (or level
1).
H Limiting Functions by Function Level
The following table shows how functions are limited by the function level settings. The “Yes” indicates
that that function is enabled and “No” indicates that the function is disabled.
Classifi-
Function Contents
Function level
Refer-
cation
0
(Moni-
tor
only)
1
(Basic
opera-
tion/
monitor
only)
2
(All
func-
tions)
ence
Initial
Resolution selection (setting)
Set the resolution for
No Yes Yes
3-5-2
se
ngs
Resolution selection
(operation)
one
eso
ver
ro
a
on.
(360 or 720
divisions/rotation)
Yes Yes Yes
Rotation direction selection
(setting)
Select either CW or
CCW direction.
Yes Yes Yes
3-5-2
Rotation direction selection
(operation)
Yes Yes Yes
Operation Chapter 3