0Function level 1 2
3-44
3-6 Applied Functions
Function selection (Function No. U) must be set to “2” (all functions) before the applied
functions can be used for 3F88L-160/162 Cam Positioners.
3-6-1 Function Level Selection Setting (SET Mode)
H Function Level Selection Setting and Checking
Check if the function level is set to function level 2 (all functions). If another function level is set, change
the setting to function level 2 (all functions).
Function
No.
Parameter
No.
Function
name
Setting
range
Details
U (u)
1 Function
level
selection
0 to 2 0: Function level 0 (monitor only)
1: Function level 1 (basic operation/monitor
only) (factory setting)
2: Function level 2 (all functions)
D Procedure
Set the function level selection to “2” (function level 2).
Operation Display Explanation
Use the mode selection switch to change to SET mode.
BANK/
FUN
Keep pressing the Bank/Function Key until “U” appears on the display.
Note The display will change from 12....8AtU1.. in the
basic settings.
SET
Press the Set Key to allow settings to be made.
Cam/Parameter number display: “1”
SPEED/ON angle display: Flashes current setting
If the setting value is not “2,” use the Up Key and change the setting to
“2” (all functions).
0: Monitor 1: Basic settings 2: All functions
If the setting is not on “2,” use the Up or Down Key to change to “2”
(all functions).
0: Monitor
1: Basic settings
2: All functions