0Function level 1 2
3-44
3-6 Applied Functions
Function selection (Function No. U) must be set to “2” (all functions) before the applied
functions can be used for 3F88L-160/162 Cam Positioners.
3-6-1 Function Level Selection Setting (SET Mode)
H Function Level Selection Setting and Checking
Check if the function level is set to function level 2 (all functions). If another function level is set, change
the setting to function level 2 (all functions).
Function
No.
Parameter
No.
Function
name
Setting
range
Details
U (u)
1 Function
level
selection
0 to 2 0: Function level 0 (monitor only)
1: Function level 1 (basic operation/monitor
only) (factory setting)
2: Function level 2 (all functions)
D Procedure
Set the function level selection to “2” (function level 2).
Operation Display Explanation
Use the mode selection switch to change to SET mode.
BANK/
FUN
Keep pressing the Bank/Function Key until “U” appears on the display.
Note The display will change from 1→2→....→8→A→t→U→1→.. in the
basic settings.
SET
Press the Set Key to allow settings to be made.
• Cam/Parameter number display: “1”
• SPEED/ON angle display: Flashes current setting
If the setting value is not “2,” use the Up Key and change the setting to
“2” (all functions).
0: Monitor 1: Basic settings 2: All functions
If the setting is not on “2,” use the Up or Down Key to change to “2”
(all functions).
0: Monitor
1: Basic settings
2: All functions
Operation Chapter 3