2-14
2-3-2 Standard Wiring Method
The number of man hours required for wiring will be reduced and the reliability of the Unit
will be improved if OMRON Cables are used.
Give sufficient consideration to noise countermeasures when wiring
H Using Connection Cables
Use the following Cables to connect the Unit to peripheral devices. Always use OMRON Cables when
connecting the Resolver, in particular, to ensure reliability of the Unit.
Peripheral device
to be connected
Cable name Model Remarks
Resolver Resolver Cable
3F88L-CRjjjC
Extension Cable for 3F88L-RS17/-RS17T
3F88L-CRjjjNA
Cable for 3F88L-RS15
3F88L-CRjjjSA
Cable for 3F88L-RS15W
I/O Block Cam Output Cable
3F88L-CGjjjN
Connectors at both ends.
PC or similar device
(for cam output)
Cam Output Cable
3F88L-CGjjjS
Connector on one end.
Display Unit Cam Output Cable
3F88L-CGjjjS
Connector on one end.
Note The jjj in the cable model numbers indicates the length of the cable. Refer to 7-4 Standard
Models for details.
H Wiring for Improved Noise Resistance
The noise resistance of the system can be improved by the wiring method. The following points must be
given attention when wiring.
D Connection Method
AC power
supply
Control panel
Power
device
Control
device
Insulation
transformer
Noise filter
Surge
absorber
Control
power
supply
Cam
Positioner
Resolver
If metal ducted
2.0 mm
2
ground min.
Ground to 100 Ω or less.
Ground board
Design Chapter 2