1-4
H Data Save
Saves parameters and cam programs in non-volatile memory (EEPROM). As the data is stored in
non-volatile memory, battery replacement, and other maintenance is not required.
H Program Number Check
The number of programs and origin compensation angle can be checked. (Refer to 3-5-3 Cam Pro-
gram Creating and Checking.)
1-1-6 Initial Settings Functions
H Switching Resolution
Switches between 360 and 720 divisions per Resolver revolution. (Refer to 3-5-2 Initial Settings.)
H Changing Rotation Direction
Sets the direction of increasing angle to suit the mechanical configuration. (Refer to 3-5-2 Initial Set-
tings.)
1-1-7 Applied Functions
H Origin Compensation
Sets any angle to 0° according to the mechanical origin. (Refer to 3-6-4 Origin Compensation and
Origin Shift.)
H Origin Shift
Sets any angle to 0° according to the mechanical origin when the trigger turns ON in RUN mode. (Re-
fer to 3-6-4 Origin Compensation and Origin Shift.)
H Backlash Compensation
Sets a difference between the detection angles in CW and CCW directions to absorb mechanical
vibration. (Refer to 3-6-5 Backlash Compensation..)
H Advance Angle Compensation
Advances the cam output angle in proportion to the number of Resolver revolutions. (Refer to 3-6-6
Advance Angle Compensation.)
H Cam Protect
Protects each bank and cam to prevent the cam ON/OFF data being inadvertently changed or de-
leted.
H One-direction Function Setting
Enables cam output in one rotational direction only. (Refer to 3-6-8 One-direction Function.)
Outline Chapter 1