1-5
H Output Hold Function
• Holds the immediately preceding cam output status when the user switches to PRGM mode or when
there is an error. (Refer to 3-6-9 Output Hold Function.)
H Present Value Output Function
• Uses the cam output signal and outputs the signal to the Display Unit (M7E, M7F, or other Display
Units.) The present angle or number of revolutions can be displayed on the Display Unit. (Refer to
3-6-10 Present Value Output Function.)
H Pulse Output Function
• Automatically sets data that turns ON and OFF at regular intervals in a desired bank or cam in order to
edit memory contents. (Refer to 3-6-11 Pulse Output Function.)
H Teaching
• The Resolver angle data may be input as cam program settings during manual operation of the
machinery. (Refer to 3-6-12 Teaching.)
H Copy Function
• By making the settings for one Cam Positioner, the cam program, the various compensation values,
and settings in one operation may be copied to another Cam Positioner.
H Trial Operation
• When adjusting the ON/OFF angles to suit the machinery, performs cam output and changes the ON/
OFF angle in real time regardless of the control input signal status. (Refer to 3-6-14 Trial/Adjustment
Operation.)
H Compensation Operation
• When adjusting the ON/OFF angles to suit the machinery, changes the ON/OFF angles in real time
while in operation status (cam output status). (Refer to 3-6-14 Trial/Adjustment Operation.)
H Communications Function
• Has a communications port that conforms to shape B in CompoWay/F. Communications can be used
to read and write cam programs and monitor present angles and number of revolutions. (Refer to
Chapter 4 Communications.)
Note CompoWay/F is a uniform procedure in OMRON serial communications. CompoWay/F has uni-
form frame formats and commands that conform to FINS (Factory Interface Network Service) that
is used in OMRON PCs. It facilitates easier communications between multiple components and
between personal computers and components.