3-39
Operation ExplanationDisplay
Bank selection input
(BANK1 to 3)
Use the control input bank selection input (BANK1 to 3) to
specify the bank number to be used.
Set bank number
(BANK 1 to 3)
E.g.:To set bank No. 2:
BANK 1:ON
BANK 2: OFF
BANK 3: OFF
24 V DC
RUN
Note Refer to 3-5-8 Control I/O Signals for information on the
relationship between bank selection input (BANK1 to 3)
and execution bank numbers.
Operation start input
(START)
Turn ON the operation start input signal (START) for control
input.
When cam output is enabled, the control output RUN output
signal (RUN) is turned ON.
Turn ON the operation
start signal (START).
24 V DC
24V
Note When the operation start signal (START) is turned ON,
“ru” will appear in the Cam/Parameter No. display.
Machinery operation
starts
Start up the machinery and start operation.
Note Observe the movement of peripheral devices to check if
the cam output signals are being output at the correct
timing.
Note 1. To change the ON and OFF angles, follow the directions in 3-5-3 Cam Program Creating and Checking
and change the angle data.
Note 2. Use the compensation operation function to change the angle data during operation. Refer to 3-6 Ap-
plied Functions for details.
Operation Chapter 3