Function level 2
3-70
H Related Parameters (SET Mode)
D Cam Protect
Function
No.
C (c)
Parameter
No.
--- Setting range ---
Use this parameter to set or release cam protection for individual banks and cams.
The factory setting is “no cam protection for any cam.”
Note This parameter is enabled when the power is turned OFF and then turned ON again.
Cam Protect Display
w SPEED/ON w POSITION/OFF
The cam protect status for a particular cam number is shown by the ON/OFF status of the a 7-segment
indicator.
ON: Cam protected
OFF: Not cam protected
Note The 3F88L-160 (16-point model) Cam Positioner does not have cam numbers 17 to 32. (Those
indicators will remain OFF).