3-76
Operation
One-direction function (bank number 1)
One-direction
function (bank
number 1, cam
number 1))
One-direction
function (bank
number 1, cam
number 32)
Use the mode selection switch to change to SET mode.
One-direction function setting
Up to cam number 16 for 3F88L-160.
One-direction function (bank number 2)
One-direction
function (bank
number 2, cam
number 1))
One-direction
function (bank
number 2, cam
number 32)
Up to cam number 16 for 3F88L-160.
One-direction function (bank number 8)
One-direction
function (bank
number 8, cam
number 1))
One-direction
function (bank
number 8, cam
number 32)
Up to cam number 16 for 3F88L-160.Up to bank number 4 for
720 resolution.
Bank selection
enabled status
One-direction function
setting enabled status
Use the Bank/Function Key to set the one-direction function (Function No. F) and press the Set Key to
make the bank number flash in the Bank/Function display (bank selection enabled status). Use the Up
and Down Keys to set the bank number that contains the cam for which one-direction function is to be
set.
Next, press the Set Key to display the cam number in the Cam/Parameter No. display. The present
settings will flash in the POSITION/OFF display (one-direction function setting enabled status).
While the bank and cam numbers are displayed (one-direction function setting enabled status), press
the Cam/Parameter Key to change the cam number. Set the cam number for which the one-direction
function is to be set.
Use the Up and Down Keys to set the data.
Press the Set Key. The data will remain lit for approximately one second, the data will be confirmed,
and the display will start flashing again.