EasyManua.ls Logo

Omron CJ - INSTRUCTIONS - Page 1186

Omron CJ - INSTRUCTIONS
1308 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1148
CS/CJ/NSJ Series Instructions Reference Manual (W474)
4. Instruction Execution Times and Number of Steps
4-1-3 Sequence Control Instructions
4-1-4 Timer and Counter Instructions
SINGLE BIT OUTPUT OUTB 2 0.19 0.280 ---
!OUTB 16 0.99 1.180 ---
Instruction Mnemonic Length
(steps)
ON execution time (µs) Conditions
CJ2H
CPU6@(-EIP)
CJ2M CPU@@
END END 1 2.6 3.5 ---
NO OPERATION NOP 1 0.016 0.040 ---
INTERLOCK IL 1 0.048 0.060 ---
INTERLOCK CLEAR ILC 1 0.048 0.060 ---
MULTI-INTERLOCK DIFFER-
ENTIATION HOLD
MILH 3 2.3 3.3 Interlock condition
not met (input condi-
tion ON)
3.4 4.6 Interlock condition
met (input condition
OFF)
3.8 5.2 Interlock condition
met again during
interlock (input con-
dition OFF)
MULTI-INTERLOCK DIFFER-
ENTIATION RELEASE
MILR 3 2.3 3.1 Interlock condition
not met (input condi-
tion ON)
3.4 4.5 Interlock condition
met (input condition
OFF)
3.8 5.1 Interlock condition
met again during
interlock (input con-
dition OFF)
MULTI-INTERLOCK CLEAR MILC 2 1.2 1.7 Not during interlock
1.6 2.2 During interlock
JUMP JMP 2 0.31 0.34 ---
JUMP END JME 2 --- --- ---
CONDITIONAL JUMP CJP 2 0.31 0.34 Jump condition met
(input condition ON)
CONDITIONAL JUMP NOT CJPN 2 0.31 0.34 Jump condition met
(input condition
OFF)
MULTIPLE JUMP JMP0 1 0.048 0.060 ---
MULTIPLE JUMP END JME0 1 0.048 0.060 ---
FOR LOOP FOR 2 0.27 0.42 Designating a
constant
BREAK LOOP BREAK 1 0.048 0.060 ---
NEXT LOOP NEXT 1 0.14 0.16 When loop is contin-
ued
0.18 0.18 When loop is ended
Instruction Mnemonic Length
(steps)
ON execution time (µs) Conditions
CJ2H
CPU6@(-EIP)
CJ2M CPU@@
HUNDRED-MS TIMER TIM 3 0.67 0.84 ---
TIMX 0.67 0.84
Instruction Mnemonic Length
(steps)
ON execution time (µs) Conditions
CJ2H
CPU6@(-EIP)
CJ2M CPU@@

Table of Contents