● ERRGET
Acquire Error Information
This command acquires the latest error code from the Sensor.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Error code Returns the latest error code. If there is no error history, the response is 00000000.
11-1 Error Histories: p. 398
ER
CR
RG TE
Command
Delimiter
00 0
CR
00 000
Delimiter
Model
CR
OK
Delimiter