Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
380
FQ2 User’s Manual
Clearing Measurement Values: 280F 00102010
This command clears the measurement values.
● Command Format
● Response Format
● End Codes
Clearing Errors: 280F 00102040
This command clears the error output status (error output and error indicator).
● Format
● Response Format
● End Codes
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F 00102010
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 00102010
End code (hex) Meaning
0000 Command execution ended normally.
FFFF Command execution ended in an error.
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F 00102040
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 00102040
End code (hex) Meaning
0000 Command execution ended normally.
FFFF Command execution ended in an error.