2 Instruction Descriptions
2-252
NJ-series Instructions Reference Manual (W502)
The following table shows the valid ranges for In and Out according to their data types.
To convert data with any data type to a real number, use a TO_** (Real Number Conversion Group)
instruction (page 2-281).
Always use the correct instruction name for the data types of In and Out.
If the value of In is positive or negative infinity, the value of Out is positive or negative infinity.
If the value of In is nonnumeric data, the value of Out is nonnumeric data.
If the conversion result exceeds the valid range of Out, the value of Out will be infinity with the same
sign as the value of In.
For the LREAL_TO_REAL instruction, if the value of In is closer to 0 than ±1.175494e38, the value
of Out will be 0.
Data type of In Data type of Out Valid range for In and Out
REAL LREAL 3.402823e+38 to 3.402823e+38
or +/−∞
LREAL REAL
Additional Information
Precautions for Correct Use
In
Out=abc
REAL data
LREAL data
REAL#3.141592e+0
3.141592e+0