2-527
2 Instruction Descriptions
NJ-series Instructions Reference Manual (W502)
Text String Instructions
2
FIND
Make sure the number of characters in In2 is less than the number of characters in In1. Otherwise,
the value of Out will be 0.
If In2 exists more than once in In1, the position of the first In2 from the beginning of In1 is assigned to
Out.
If the value of In1 and In2 is only the NULL character, the value of Out is 1.
Multi-byte characters are counted as one character each.
An error occurs in the following cases. ENO will be FALSE, and Out will not change.
In1 or In2 does not end in a NULL character.
In1 or In2 results in a character code error.
Precautions for Correct Use