2 Instruction Descriptions
2-642
NJ-series Instructions Reference Manual (W502)
• This instruction will not end in an error even if restart processing is in progress for the Unit specified
by UnitNo. The value of Busy remains at TRUE and the value of Done changes to TRUE when restart
processing is finished. Restart requests are not queued.
• The Unit is restarted if the value of Execute is TRUE when operation starts.
• An error occurs in the following cases. Error will change to TRUE.
• The value of UnitNo is outside of the valid range.
• The Unit specified with UnitNo does not exist.
• Restart processing failed.
When the value of Tr i g g e r changes to TRUE, the baud rate of serial port 1 on the Serial Communica-
tions Unit with a unit number of 0 is set to 38,400 bps and the Unit is restarted.
Definitions of Global Variables
Precautions for Correct Use
Sample Programming
USINT
0
Global Variables
SCU_P1_BaudrateCfg
Baud rate
IOBus://rack#0/slot#0
/P1_BaudrateCfg
Name
Data type
Initial value CommentAT specification Retain