2-565
2 Instruction Descriptions
NJ-series Instructions Reference Manual (W502)
Time and Time of Day Instructions
2
C O NC AT_DAT E_TO D
The CONCAT_DATE_TOD instruction combines a date In1 and a time of day In2. The result of combin-
ing in Out is also a date and time.
The following example is for when In1 is D#1970-1-7 and In2 is TOD#23:59:59.999999999.
An error occurs in the following case. ENO will be FALSE, and Out will not change.
The results of combining exceeds the valid range of Out (e.g., the value of In1 is D#2554-7-21 and
the value of In2 is larger than TOD#23:34:33.709551615).
Function
Related System-defined Variables
Name Meaning Data type Description
_CurrentTime System Time of Day DT The time of day from the system clock. The num-
ber of seconds from 00:00:00 on January 1,1970.
Precautions for Correct Use
abc:=CONCAT_DATE_TOD(D#1970-1-7,
TOD#23:59:59.999999999);
LD
ST
abc
D#1970-1-7
TOD#23:59:59.999999999
CONCAT_DATE_TOD
EN ENO
In1
In2
+
D#1970-1-7
TOD#23:59:59.999999999
DT#1970-1-7-23:59:59.999999999
In1
In2
Out=abc