10-85
10 Sample Programming
NJ/NX-series CPU Unit Motion Control Users Manual (W507)
10-2 Basic Programming
Samples
10
10-2-16 Changing a Cam Data Variable and Saving the Cam Table
// MC_Power for axis 0
PWR1(
Axis := MC_Axis000,
Enable := Pwr1_En,
Status => Pwr1_Status,
Busy => Pwr1_Bsy,
Error => Pwr1_Err,
ErrorID => Pwr1_ErrID
);
// MC_Power for axis 1
PWR2(
Axis := MC_Axis001,
Enable := Pwr2_En,
Status => Pwr2_Status,
Busy => Pwr2_Bsy,
Error => Pwr2_Err,
ErrorID => Pwr2_ErrID
);
// MC_Home for axis 0
HM1(
Axis := MC_Axis000,
Execute := Hm1_Ex,
Done => Hm1_D,
Busy => Hm1_Bsy,
CommandAborted => Hm1_Ca,
Error => Hm1_Err,
ErrorID => Hm1_ErrID
);
// MC_Home for axis 1
HM2(
Axis := MC_Axis001,
Execute := Hm2_Ex,
Done => Hm2_D,
Busy => Hm2_Bsy,
CommandAborted => Hm2_Ca,
Error => Hm2_Err,
ErrorID => Hm2_ErrID
);
//MC_MoveVelocity
VEL(
Axis := MC_Axis000,
Execute := Vel_Ex,
Velocity := Vel_Vel,
Acceleration := Vel_Acc,
Deceleration := Vel_Dec,
Direction := Vel_Dir,
InVelocity => Vel_InVel,
Busy => Vel_Bsy,
Active => Vel_Act,
CommandAborted => Vel_Ca,
Error => Vel_Err,
ErrorID => Vel_ErrID
);