EasyManua.ls Logo

Omron ZX-E - Page 41

Omron ZX-E
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
ZX-E
Operation Manual
Section 2 Wiring Output Cables
Section 2
PREPARATIONS FOR MEASUREMENT
I/O Circuit Diagrams
NPN Amplifier Unit
Load
Load
Load
Current output: 300 max.
Voltage output: 10 k min.
Load
Current output
(4 to 20 mA)
Current/voltage
output selector
Internal circuit
Brown
12 to 24 V DC
White
HIGH judgement
output
Green
PASS judgement output
Gray
LOW judgement output
12 to 24 V DC
Blue GND (0 V)
Pink Judgement output hold input
Purple Timing input
Orange Zero reset input
Red Reset input
Black
Linear output
Shield Linear ground
Voltage
output
(±4 V)
100
Z166-E1-02A.book Page 39 Friday, June 3, 2005 4:18 PM

Table of Contents