EasyManua.ls Logo

Omron ZX-E - Page 42

Omron ZX-E
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
Section 2 Wiring Output Cables
ZX-E
Operation Manual
Section 2
PREPARATIONS FOR MEASUREMENT
PNP Amplifier Unit
Load
Current output: 300 max.
Voltage output: 10 k min.
Current output
(4 to 20 mA)
Current/voltage
output selector
Internal circuit
Brown
12 to 24 V DC
White
HIGH judgement
output
Green
PASS judgement output
Gray
LOW judgement output
12 to
24
V DC
Blue GND (0 V)
Pink Judgement output hold input
Purple Timing input
Orange Zero reset input
Red Reset input
Black
Linear output
Shield Linear ground
Voltage
output
(±4 V)
100
Load
Load
Load
Z166-E1-02A.book Page 40 Friday, June 3, 2005 4:18 PM

Table of Contents

Related product manuals