Airflow Precautions
20 SPARC T5-4 Server Installation Guide • July 2015
TABLE 2
Shock and Vibration Specifications
Description Operating Notes
Shock 3G, 11 ms Half-sine
Vibration (vertical) 0.15G 5 to 500 HZ swept-sine
Vibration (horizontal) 0.10G
TABLE 3
Acoustic Specifications
Description Operating at Idle Operating at Peak Power
Acoustic power (LwAd 1B= 10 dB) 7.8B 9.4B
Acoustic pressure level (LpAm:
bystander positions)
61.8 dBA 79.7 dBA
Related Information
■
Server Safety and Compliance
■
“Physical Specifications” on page 17
■
“Electrical Specifications” on page 18
■
“Environmental Requirements” on page 19
■
“Airflow Precautions” on page 20
Airflow Precautions
Caution - Proper airflow is essential for keeping the server's internal temperatures within a safe
operating range.
Air flows from the front to the rear of the server.
Follow these guidelines to ensure unrestricted airflow in the server: