Addresses and codes list
12.8.8 Remote-OUT function setting (R-OUT)
Modbus communication
Register address
Name Setting range Initial value Update
Upper Lower
4640
(1220h)
4641
(1221h)
R-OUT0 output function selection
Refer to "Output signals
list."
(p.120)
64: M0_R
C
4642
(1222h)
4643
(1223h)
R-OUT1 output function selection 65: M1_R
4644
(1224h)
4645
(1225h)
R-OUT2 output function selection 66: M2_R
4646
(1226h)
4647
(1227h)
R-OUT3 output function selection 58: FWD (START/STOP)_R
*
4648
(1228h)
4649
(1229h)
R-OUT4 output function selection 59: REV (RUN/BRAKE)_R
*
4650
(122Ah)
4651
(122Bh)
R-OUT5 output function selection 72: STOP-MODE (FWD/REV)_R
*
4652
(122Ch)
4653
(122Dh)
R-OUT6 output function selection 135: INFO
4654
(122Eh)
4655
(122Fh)
R-OUT7 output function selection 129: ALM-A
4656
(1230h)
4657
(1231h)
R-OUT8 output function selection 136: SYS-BSY
4658
(1232h)
4659
(1233h)
R-OUT9 output function selection 148: DIR
4660
(1234h)
4661
(1235h)
R-OUT10 output function selection 168: MPS
4662
(1236h)
4663
(1237h)
R-OUT11 output function selection 0: Not used
4664
(1238h)
4665
(1239h)
R-OUT12 output function selection 0: Not used
4666
(123Ah)
4667
(123Bh)
R-OUT13 output function selection 134: MOVE
4668
(123Ch)
4669
(123Dh)
R-OUT14 output function selection 141: VA
4670
(123Eh)
4671
(123Fh)
R-OUT15 output function selection 140: TLC
*
If the "3-wire mode" is set with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be
applied.