34
Parameter
Parameter name Setting range Factory setting Update
Reference
page
Communication and I/F function
RS-485 communication timeout alarm
0: Not monitored
1 to 10000 ms
0
A
P.46
RS-485 communication error alarm
0: Disable
1 to 10 times
3
Transmission waiting time 0.0 to 1000.0 ms 3.0
D
Silent interval
0.0: Set automatically
0.1 to 10.0 ms
0.0
Slave error response mode
0: Normal response is
returned
1: Exception response is
returned
1 A
Initial group ID
–1: Disable
(no group transmission)
1 to 15: Group ID
Do not use 0.
−1 C
Indirect reference address setting (0)
0 to 65535
(0 to FFFFh)
576: Operation data No.0 rotation speed
A
Indirect reference address setting (1) 896: Operation data No.0 torque limiting value
Indirect reference address setting (2) 768: Operation data No.0 acceleration time
Indirect reference address setting (3) 832: Operation data No.0 deceleration time
Indirect reference address setting (4) 62: Driver input command
Indirect reference address setting (5) 98: Selection number
Indirect reference address setting (6) 103: Feedback speed
Indirect reference address setting (7) 108: Load factor
Indirect reference address setting (8) 63: Remote output
Indirect reference address setting (9) 64: Present alarm
Indirect reference address setting (10) 123: Information
Indirect reference address setting (11) 124: Driver temperature
Indirect reference address setting (12) 163: Inverter voltage
Indirect reference address setting (13) 157: Rotation amount meter
Indirect reference address setting (14) 127: Tripmeter
Indirect reference address setting (15) 126: Odometer
Indirect reference address setting (16) 160: Main power supply time
Indirect reference address setting (17) 161: Main power supply count
Indirect reference address setting (18) 184: I/O status 1
Indirect reference address setting (19) 185: I/O status 2
Indirect reference address setting (20) 186: I/O status 3
Indirect reference address setting (21) 187: I/O status 4
Indirect reference address setting (22) 188: I/O status 5
Indirect reference address setting (23) 189: I/O status 6
Indirect reference address setting (24) 190: I/O status 7
Indirect reference address setting (25) 191: I/O status 8
Indirect reference address setting (26) 0: Not used
Indirect reference address setting (27) 0: Not used
Indirect reference address setting (28) 0: Not used
Indirect reference address setting (29) 0: Not used
Indirect reference address setting (30) 0: Not used
Indirect reference address setting (31) 0: Not used