33
Parameter
Parameter name Setting range Factory setting Update
Reference
page
Remote-IN function selection, Remote-OUT function selection
R-IN0 input function selection
Refer to p.58.
64: M0
C P.45
R-IN1 input function selection 65: M1
R-IN2 input function selection 66: M2
R-IN3 input function selection 58: FWD (START/STOP)
*
R-IN4 input function selection 59: REV (RUN/BRAKE)
*
R-IN5 input function selection 72: STOP-MODE (FWD/REV)
*
R-IN6 input function selection 0: Not used
R-IN7 input function selection 8: ALM-RST
R-IN8 input function selection 0: Not used
R-IN9 input function selection 0: Not used
R-IN10 input function selection 0: Not used
R-IN11 input function selection 0: Not used
R-IN12 input function selection 0: Not used
R-IN13 input function selection 0: Not used
R-IN14 input function selection 0: Not used
R-IN15 input function selection 0: Not used
R-OUT0 output function selection
Refer to p.58.
64: M0_R
R-OUT1 output function selection 65: M1_R
R-OUT2 output function selection 66: M2_R
R-OUT3 output function selection 58: FWD (START/STOP)_R
*
R-OUT4 output function selection 59: REV (RUN/BRAKE)_R
*
R-OUT5 output function selection 72: STOP-MODE (FWD/REV)_R
*
R-OUT6 output function selection 135: INFO
R-OUT7 output function selection 129: ALM-A
R-OUT8 output function selection 136: SYS-BSY
R-OUT9 output function selection 148: DIR
R-OUT10 output function selection 168: MPS
R-OUT11 output function selection 0: Not used
R-OUT12 output function selection 0: Not used
R-OUT13 output function selection 134: MOVE
R-OUT14 output function selection 141: VA
R-OUT15 output function selection 140: TLC
Communication and I/F function
USB-ID enable
0: Disable
1: Enable
1
D
P.46
USB-ID 0 to 999,999,999 0
USB-PID 0 to 31 0
RS-485 Receive packet monitor
0: All
1: Only own address
0 A
Communication ID
−1: The switch setting of the driver is followed
1 to 15: Slave address 1 to 15
※
Do not use 0.
−1
D
Baudrate
0: 9,600 bps
1: 19,200 bps
2: 38,400 bps
3: 57,600 bps
4: 115,200 bps
5: 230,400 bps
4
Communication order
0: Even Address-High Word & Big-Endian
1: Even Address-Low Word & Big-Endian
2: Even Address-High Word & Little-Endian
3: Even Address-Low Word & Little-Endian
0
Communication parity
0: None
1: Even parity
2: Odd parity
1
Communication stop bit
0: 1 bit
1: 2 bits
0
*
If the 3-wire mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( ) will be applied.