Table 1. PMCS - BEFORE - Continued
Item
No.
Interval
Item to
be
Checked
or
Serviced
Procedure
Equipment
Not Ready/
Available If:
With
Trailer
Coupled
release handle (2) are
completely in.
1
2
Figure 5.
7
Before Trailer Air
Brake
Hoses
and
Electrical
Cable
1. Check that service coupling (1),
intervehicular electrical cable (2),
and emergency coupling (3) are
securely connected to trailer.
Either air
brake hose
or electrical
cable can-
not be con-
TM 9-2320-360-10 0100