Error message Error no. Contents Cause Possible measure
Left Lamp Short 7205 Short circuit in elec
trical circuit of left
front/rear light
Right Lamp Short 7209 Short circuit in elec
trical circuit of right
front/rear light
e.g.defective plug
connection, cable
break
Defective front/rear
light
Check plug connec
tions and cable to
front/rear light
If error persists: con
tact specialist dealer
L Ind Lamp Short 7206 Short circuit in elec
trical circuit of left
direction indicator
R Ind Lamp Short 720A Short circuit in elec
trical circuit of right
direction indicator
e.g.defective plug
connection, cable
break
Defective direction
indicator signal
Check plug connec
tions and cable to
direction indicator
If error persists: con
tact specialist dealer
L Ind Lamp Failed 7207 Error in electrical cir
cuit of left direction
indicator
R Ind Lamp Failed 7208 Error in electrical cir
cuit of right direction
indicator
e.g.defective plug
connection, cable
break
Defective bulb
Check plug connec
tions and cable to
direction indicator
If error persists: con
tact specialist dealer
Over-current (None) Amount of current in
an actuator circuit
too great
e.g.defective plug
connection, cable
break
Defective servomotor
(actuator) or control
ler
Check plug connec
tions and cable to
servomotor; verify
that actuating drive
can move freely
If error persists: con
tact specialist dealer
Overtemp. (Acts) (None) Temperature on actu
ator circuits on con
troller too high
e.g.defective plug
connections
Defective servomotor
(actuator)
Cool down phase
Check plug connec
tions and cable to
actuator
In case of recur
rence: contact spe
cialist dealer
Overtemp. (Lamps) (None) Temperature on the
light circuit on the
controller too high
e.g.defective plug
connections
Defective lamp
Cool down phase
Check plug connec
tions and cable to
light
In case of recur
rence: contact spe
cialist dealer
Memory Error (None) Unspecified memory
error in control mod
ules
e.g.defective plug
connection, cable
break
Defective control
module
Contact specialist
dealer
PM Memory Error (None) Memory error in con
troller
e.g.defective plug
connection, cable
break
Defective controller
Check all plug con
nections and cables
on controller
If error persists: con
tact specialist dealer
Bad Cable (None) Error on the commu
nication cables
between control
modules
e.g.defective plug
connection, cable
break
Check all plug con
nections and cables
on the control mod
ules (incl. controller)
If error persists: con
tact specialist dealer
Module Error (None) e.g.unspecified error Check all plug con
109490E75=1_C