7-13
Following adjustments are required depending on the types of connected equipment.
1. With FPΣ (when the connected equipment are also the combination of FPΣ and AFPG806)
When PC(PLC) link mode: Adjustment is not required.
When general communication mode: Adjust timing by ladder program.
When computer link mode: Adjust timing by SYS1 instruction.
2. With other PLC
When PC(PLC) link mode: Not used.
When general communication mode: Adjust timing by ladder program.
3. With computer
Adjust timing by wait instruction system.
4. With other equipment’s
Confirm the time after receiving data until a transmission starts with makers.
KT temperature controller and inverters (VF-7E and VF-8X) can be used without any adjustment, as
the time taken up to a response is more than 1 ms.
GT series indicator cannot be used.
With GV series indicator, set the transmission delay time (communication parameter) to 1 ms or more.