EasyManuals Logo

Panasonic FP E Series User Manual

Panasonic FP E Series
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #163 background imageLoading...
Page #163 background image
7-13
Following adjustments are required depending on the types of connected equipment.
1. With FPΣ (when the connected equipment are also the combination of FPΣ and AFPG806)
When PC(PLC) link mode: Adjustment is not required.
When general communication mode: Adjust timing by ladder program.
When computer link mode: Adjust timing by SYS1 instruction.
2. With other PLC
When PC(PLC) link mode: Not used.
When general communication mode: Adjust timing by ladder program.
3. With computer
Adjust timing by wait instruction system.
4. With other equipment’s
Confirm the time after receiving data until a transmission starts with makers.
KT temperature controller and inverters (VF-7E and VF-8X) can be used without any adjustment, as
the time taken up to a response is more than 1 ms.
GT series indicator cannot be used.
With GV series indicator, set the transmission delay time (communication parameter) to 1 ms or more.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP E Series and is the answer not in the manual?

Panasonic FP E Series Specifications

General IconGeneral
BrandPanasonic
ModelFP E Series
CategoryController
LanguageEnglish

Related product manuals