6-6
6.2.2 Functions Used and Restrictions
Restrictions on channels/maximum counting speed (frequency)
The same channel cannot be used by more than one function. The maximum frequency when using the
high-speed counter and pulse output function is determined by the combination, as shown in the table
below.
A: Available
Channel being used
Max. counting speed
(frequency) [kHz]
High-speed counter Pulse output
High-speed
counter
Pulse output
Single phase 2-phase Independence
CH0 CH1 CH2 CH3 CH0 CH2 CH0 CH2
Interpo-
lation
Single
phase
2-
phase
Inde-
pen-
dence
Inter-
pola-
tion
A 50
A 50
A 50
A 50
A A 30
A A 30
A A 30
A A 30
A A 30
A A 30
A A A 20
A A A 20
A A A 20
A A A 20
A 20
A A 20 15
A A 20 15
A A A 20 15
A 20
A A 20 15
A A 20 15
A A A 20 15
A A 15
A 100
A
Note3)
A 30 60
A
Note3)
A A 20 45
A A A A 20 30
A A 15 45
A A A 20 15 30
A 100
A
Note3)
A 30 60
A
A
Note3)
A 20 45
A A A A 20 30
A A 15 45
A A A 20 15 30