38
7.6. Required Adjustments after Part Replacement
Note: *1
When All Position in Sec. Adjustment (P.50) is done, the setting values except for the values set for the Individual Position in
Sec. Adjustment (P.50) will be also changed.
Replaced circuit board assembly or part
Adjustment required Remarks
IC4 (FLASH memory on CONTROL Board)
1. Adjust Shading.
IC5 (EEPROM on CONTROL Board) or CONTROL
Board
1. Execute Sensor Sensitive Level in Sec.
Adjustment
(P. 5 0 ).
2. Execute Double Feed in Sec.
Adjustment (P. 5 0) to
adjust the double feed sensitivity.
3. Adjust Shading. (Only when replacing CONTROL
Board assembly.)
4. Adjust All Position.
5. Adjust Individual position manually, as required.
6. Set USB ID. (See.
Adjustment (P. 50 ))
7. In Sleep Mode, set the “Power Off” condition to “240
min”. for KV-S1057C-U / S1027C-U / SL1056-U
*1
Starting Sensor or STARTING SENSOR Board 1. Execute Sensor Sensitive Level in Sec. Adjustment
(P. 5 0 ) to adjust the Start Sensor's sensitivity.
2. Execute Double Feed in Sec.
Adjustment (P. 5 0) to
adjust the double feed sensitivity. (Only when replac-
ing Starting Sensor)
3. Adjust All Position or the following positions:
a. Adjust Length in Individual Position.
b. Adjust Paper-end Position in Individual Position.
c. Adjust Front Vertical Position in Individual Position.
d. Adjust Back Vertical Position in Individual Position.
*1
Double Feed Detector [Generator] or ULTRASONIC
SENSOR (G) Board
1. Execute Double Feed in Sec. Adjustment (P. 50 ) to
adjust the double feed sensitivity.
CIS (F) 1. Adjust Shading.
2. Adjust All Position or Front Horizontal Position in
Individual Position.
*1
CIS (B) 1. Adjust Shading.
2. Adjust All Position or Back Horizontal Position in
Individual Position.
*1
Scanning Glass (F) 1. Adjust Shading.
Scanning Glass (B) 1. Adjust Shading.
Conveyor Roller 1. Adjust Length in Individual Position, or adjust All
Position.
*1
Exit Roller 1. Adjust Length in Individual Position, or adjust All
Position.
*1
Others (when assembling or disassembling parts which
will affect the scanning positions.)
1. Adjust the following adjustment or All Position:
a. Adjust Front Vertical Position in Individual
Position.
b. Adjust Front Horizontal Position in Individual
Position.
c. Adjust Back Vertical Position in Individual
Position.
d. Adjust Back Horizontal Position in Individual
Position.