2.2 PT Programming—Procedures
24 Programming Manual
[101] Hunting Type
Selects the hunting type for each group.
Notes
Circular: Circulates until the call is answered.
Terminate: Terminates at the last extension.
Conditions
• This program is available when the extension group is enabled in [100] Hunting Group Set.
Programming Manual References
[100] Hunting Group Set
[600] Extension Group
Feature Manual References
1.1.67 Idle Extension Hunting
[102] DTMF Integration Port
Enables the extension jack number(s) (07, 08, 15, 16) to be connected to a Panasonic VPS and specified
as the voice mail ports.
Feature Manual References
1.1.121 Voice Mail Inband (DTMF) Integration
1 0 1
NEXT
extension group no. name*
STORE END
(1
…
8/ )
SELECT
SELECT
NEXT PREV
or
To continue
To continue
( Terminate/
Circular)
1 0 2
NEXT
extension jack no. name*
STORE END
(07, 08, 15, 16/ )
SELECT
SELECT
NEXT PREV
or
To continue
To continue
(Enable/
Disable)