2.2 PT Programming—Procedures
44 Programming Manual
[419] Automatic Designated Line Access
Specifies which outside (CO) line is seized automatically when an extension user dials the Automatic Line
Access number (9).
Feature Manual References
1.1.72 Line Access, Automatic
1.1.76 Line Preference—Outgoing
[420] CPC Signal Detection—Incoming
Selects the length of time required by the PBX to detect a CPC signal from an incoming outside (CO) line
call before disconnecting the line.
Notes
CPC signal detect time selection number:
00: Disable; 01–75: 22–614 ms (detect time: 8 ms increments)
Programming Manual References
[421] CPC Signal Detection—Outgoing
Feature Manual References
1.1.31 Calling Party Control (CPC) Signal Detection
4 1 9
NEXT
CO line no. name*
STORE END
(1
8/ )
SELECT
SELECT
NEXT PREV
or
To continue
To continue
( Enable/
Disable)
4 2 0 X
NEXT
CO line no.
STORE END
(1
8/ )
SELECT
NEXT PREV
or
To continue
To continue
(00
75)
42 (350 ms)

Table of Contents