EasyManua.ls Logo

Panasonic MINAS A5 Series - Page 127

Panasonic MINAS A5 Series
477 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-79
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
Parametr
No.
Title Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode
Detail
page
Class
No.
A,B
-frame
C
-frame
D,E,F
-frame
G,H
-frame
PSTF
430
Analog input 3 (AI3) overvoltage
setup
0 to 100 0 0.1V
*
○○○○
4-39
431
Positioning complete (In-position)
range
0 to 262144
10
Command
unit
○○
432
Positioning complete (In-position)
output setup
0 to 3
0
ï
○○
4 33 INP hold time 0 to 30000
0
1ms
○○
4 34 Zero-speed 10 to 20000
50
r/min
○○○○
4-40
4 35 Speed coincidence range 10 to 20000
50
r/min
4 36 At-speed (Speed arrival) 10 to 20000
1000
r/min
○○
4-41
437
Mechanical brake action at stalling
setup
0 to 10000
0
1ms
○○○○
438
Mechanical brake action at running
setup
0 to 10000
0
1ms
○○○○
4 39 Brake release speed setup 30 to 3000
30
r/min
○○○○
4-42
4 40 Selection of alarm output 1 0 to 10
0
ï
○○○○
4 41 Selection of alarm output 2 0 to 10
0
ï
○○○○
442
2nd Positioning complete (In-position)
range
0 to 262144
10
Command
unit
○○
'HÀQLWLRQRIV\PEROVXQGHU´3RZHU2II2QµLIDFKDQJHLVPDGHLWZLOOEHUHÁHFWHGXSRQWKHSDUDPHWHUZKHQWKH
power to the driver is turned off and then on again.
*
'HÀQLWLRQRIV\PEROVXQGHU´5HODWHGPRGHµ3SRVLWLRQFRQWURO6YHORFLW\FRQWURO7WRUTXHFRQWURO)IXOOFORVHGFRQWURO
[Class 5] Enhancing setting
Parametr
No.
Title Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode Detail
page
Class
No.
A,B
-frame
C
-frame
D,E,F
-frame
G,H
-frame
PSTF
5 00 2nd numerator of electronic gear 0 to 2
30
0 ï
○○
4-43
5 01 3rd numerator of electronic gear 0 to 2
30
0 ï
○○
5 02 4th numerator of electronic gear 0 to 2
30
0 ï
○○
5 03 Denominator of pulse output division 0 to 262144 0 ï
○○○○
5 04 Over-travel inhibit input setup 0 to 2 1 ï
○○○○
5 05 Sequence at over-travel inhibit 0 to 2 0 ï
○○○○
5 06 Sequence at Servo-Off 0 to 9 0 ï
○○○○
4-44
5 07 Sequence at main power OFF 0 to 9 0 ï
○○○○
5 08 LV trip selection at main power OFF 0 to 1 1 ï
○○○○
4-45
5 09 Detection time of main power off 70 to 2000 70 1ms
○○○○
'HÀQLWLRQRIV\PEROVXQGHU´3RZHU2II2QµLIDFKDQJHLVPDGHLWZLOOEHUHÁHFWHGXSRQWKHSDUDPHWHUZKHQWKH
power to the driver is turned off and then on again.
*
'HÀQLWLRQRIV\PEROVXQGHU´5HODWHGPRGHµ3SRVLWLRQFRQWURO6YHORFLW\FRQWURO7WRUTXHFRQWURO)IXOOFORVHGFRQWURO
13.
Setup of Parameter and Mode
List of Parameters
Note
Parameter describes of this page is P.4-39 to P.4-45.