2-79
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
Parametr
No.
Title Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode
Detail
page
Class
No.
A,B
-frame
C
-frame
D,E,F
-frame
G,H
-frame
PSTF
430
Analog input 3 (AI3) overvoltage
setup
0 to 100 0 0.1V
*
○○○○
4-39
431
Positioning complete (In-position)
range
0 to 262144
10
Command
unit
○○
432
Positioning complete (In-position)
output setup
0 to 3
0
ï
○○
4 33 INP hold time 0 to 30000
0
1ms
○○
4 34 Zero-speed 10 to 20000
50
r/min
○○○○
4-40
4 35 Speed coincidence range 10 to 20000
50
r/min
○
4 36 At-speed (Speed arrival) 10 to 20000
1000
r/min
○○
4-41
437
Mechanical brake action at stalling
setup
0 to 10000
0
1ms
○○○○
438
Mechanical brake action at running
setup
0 to 10000
0
1ms
○○○○
4 39 Brake release speed setup 30 to 3000
30
r/min
○ ○○○○
4-42
4 40 Selection of alarm output 1 0 to 10
0
ï
○○○○
4 41 Selection of alarm output 2 0 to 10
0
ï
○○○○
442
2nd Positioning complete (In-position)
range
0 to 262144
10
Command
unit
○○
'HÀQLWLRQRIV\PEROVXQGHU´3RZHU2II2QµLIDFKDQJHLVPDGHLWZLOOEHUHÁHFWHGXSRQWKHSDUDPHWHUZKHQWKH
power to the driver is turned off and then on again.
*
'HÀQLWLRQRIV\PEROVXQGHU´5HODWHGPRGHµ3SRVLWLRQFRQWURO6YHORFLW\FRQWURO7WRUTXHFRQWURO)IXOOFORVHGFRQWURO
[Class 5] Enhancing setting
Parametr
No.
Title Range
Default
Unit
Turning
on of
power
supply
Related
Control Mode Detail
page
Class
No.
A,B
-frame
C
-frame
D,E,F
-frame
G,H
-frame
PSTF
5 00 2nd numerator of electronic gear 0 to 2
30
0 ï
○○
4-43
5 01 3rd numerator of electronic gear 0 to 2
30
0 ï
○○
5 02 4th numerator of electronic gear 0 to 2
30
0 ï
○○
5 03 Denominator of pulse output division 0 to 262144 0 ï
○ ○○○○
5 04 Over-travel inhibit input setup 0 to 2 1 ï
○ ○○○○
5 05 Sequence at over-travel inhibit 0 to 2 0 ï
○ ○○○○
5 06 Sequence at Servo-Off 0 to 9 0 ï
○○○○
4-44
5 07 Sequence at main power OFF 0 to 9 0 ï
○○○○
5 08 LV trip selection at main power OFF 0 to 1 1 ï
○○○○
4-45
5 09 Detection time of main power off 70 to 2000 70 1ms
○ ○○○○
'HÀQLWLRQRIV\PEROVXQGHU´3RZHU2II2QµLIDFKDQJHLVPDGHLWZLOOEHUHÁHFWHGXSRQWKHSDUDPHWHUZKHQWKH
power to the driver is turned off and then on again.
*
'HÀQLWLRQRIV\PEROVXQGHU´5HODWHGPRGHµ3SRVLWLRQFRQWURO6YHORFLW\FRQWURO7WRUTXHFRQWURO)IXOOFORVHGFRQWURO
13.
Setup of Parameter and Mode
List of Parameters
Note
Parameter describes of this page is P.4-39 to P.4-45.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com