2-90
Outline
To prevent operational error e.g. unintentional parameter modification, the front panel
may be locked.
Once locked, operations on the panel are limited as follows:
Mode Locked panel conditions
Monitor Mode No limitation: all monitored data can be checked.
Parameter Set up Mode No parameter can be changed but setting can be checked.
EEPROM Writing Mode Cannot be run. (No display)
Auxiliary Function Mode
Cannot be run except for “Release of front panel lock”. (No
display)
How to operate
5HODWHGSDUDPHWHUV
Parameter No.
Title Function
Class
No.
5 35 Setup of front panel lock
Locks the operation attempted from the front
panel.
Lock and unlock can be made in one of two ways.
Procedure Front panel
Setup support software
PANATERM
Lock
(1) Set Pr5.35 “Front panel lock” to 1, and writ the setting to EEPROM.
(2) Turn on power to the driver.
(3) The front panel is locked.
Unlock
(1)Execute the auxiliary function
mode, front panel lock release
function.
(2) Turn on power to the driver.
(3) The front panel is unlocked.
(1) Set Pr5.35 “Front panel lock” to 0,
and writ the setting to EEPROM.
(2) Turn on power to the driver.
(3) The front panel is unlocked.
Note
Related page
For details of front panel lock release, refer to P.2-113.
3´'HWDLOVRI3DUDPHWHUµ
2
Preparation
15. How to Use the Front Panel
Setup of front panel lock