4-39
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
Note
Related page
$SDUDPHWHULVGHVLJQDWHGDVIROORZV
Pr0.00
Parameter No.Class
)RUSDUDPHWHUVZKLFK1RKDYHDVXIIL[RI´
*
FKDQJHGFRQWHQWVZLOOEHYDOLGDWHGZKHQ
\RXWXUQRQWKHFRQWUROSRZHU
3´,QSXWVDQGRXWSXWVRQFRQQHFWRU;µ
1. Details of parameter
[Class 4] I/F monitor setting
Pr4.29
Analog input 3 (AI3) filter
Range Unit Default
Related
control mode
0 to 6400 0.01ms 0 P S T F
6HWXSWKHWLPHFRQVWDQWRIVWGHOD\ÀOWHUWKDWGHWHUPLQHVWKHODJWLPHEHKLQGWKHYROWDJH
applied to the analog input 3.
Pr4.30
Analog input 3 (AI3) overvoltage setup
Range Unit Default
Related
control mode
0 to 100 0.1V 0 P S T F
6HWXSWKHH[FHVVLYHOHYHORIWKHLQSXWYROWDJHRIDQDORJLQSXWE\XVLQJWKHYROWDJH
DVVRFLDWHGZLWKRIIVHW
Pr4.31
Positioning complete (In-position) range
Range Unit Default
Related
control mode
0 to 262144
Command
unit
10 P F
Caution
Note
6HWXSWKHWLPLQJRISRVLWLRQDOGHYLDWLRQDWZKLFKWKHSRVLWLRQLQJFRPSOHWHVLJQDO,13LVRXWSXW
The command unit is used as the default unit but can be replaced by the encoder unit by
XVLQJ3U3RVLWLRQLQJXQLWVHOHFWLRQ1RWHWKDWZKHQWKHHQFRGHUXQLWLVXVHGXQLWRI
3U3RVLWLRQDOGHYLDWLRQH[FHVVVHWXSLVDOVRFKDQJHG
)RUGHVFULSWLRQRI´FRPPDQGXQLWµDQG´HQFRGHUXQLWµUHIHUWR3´3Uµ
Pr4.32
Positioning complete (In-position)
output setup
Range Unit Default
Related
control mode
0 to 3 0 P F
6HOHFWWKHFRQGLWLRQWRRXWSXWWKHSRVLWLRQLQJFRPSOHWHVLJQDO,13
Setup value Action of positioning complete signal
[0]
7KHVLJQDOZLOOWXUQRQZKHQWKHSRVLWLRQDOGHYLDWLRQLVVPDOOHUWKDQ3U3RVLWLRQLQJ
FRPSOHWHUDQJH
1
7KHVLJQDOZLOOWXUQRQZKHQWKHUHLVQRSRVLWLRQFRPPDQGDQGWKHSRVLWLRQDO
GHYLDWLRQLVVPDOOHUWKDQ3U3RVLWLRQLQJFRPSOHWHUDQJH
2
7KHVLJQDOZLOOWXUQRQZKHQWKHUHLVQRSRVLWLRQFRPPDQGWKH]HURVSHHGGHWHFWLRQVLJQDO
LV21DQGWKHSRVLWLRQDOGHYLDWLRQLVVPDOOHUWKDQ3U3RVLWLRQLQJFRPSOHWHUDQJH
3
7KHVLJQDOZLOOWXUQRQZKHQWKHUHLVQRSRVLWLRQFRPPDQGDQGWKHSRVLWLRQDOGHYLD
tion
LVVPDOOHUWKDQ3U3RVLWLRQLQJFRPSOHWHUDQJH7KHQKROGV21VWDWXVXQWLOWKH
QH[WSRVLWLRQFRPPDQGLVHQWHUHG6XEVHTXHQWO\21VWDWHLVPDLQWDLQHGXQWLO3U
,13KROGWLPHKDVHODSVHG$IWHUWKHKROGWLPH,13RXWSXWZLOOEHWXUQHG212))DF-
FRUGLQJWRWKHFRPLQJSRVLWLRQDOFRPPDQGRUFRQGLWLRQRIWKHSRVLWLRQDOGHYLDWLRQ
Pr4.33
INP hold time
Range Unit Default
Related
control mode
0 to 30000 1ms 0 P F
6HWXSWKHKROGWLPHZKHQ3U3RVLWLRQLQJFRPSOHWHRXWSXWVHWXS 
Setup value State of positioning complete signal
[0]
7KHKROGWLPHLVPDLQWDLQHGGHÀQLWHO\NHHSLQJ21VWDWHXQWLOWKHQH[WSRVLWLRQDO
FRPPDQGLVUHFHLYHG
1 to 30000
21VWDWHLVPDLQWDLQHGIRUVHWXSWLPHPVEXWVZLWFKHGWR2))VWDWHDVWKHSRVLWLRQDO
FRPPDQGLVUHFHLYHGGXULQJKROGWLPH