7-95
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
Caution
Use options correctly after reading operation manuals of the options to better un-
derstand the precautions.
Take care not to apply excessive stress to each optional part.
[Unit: mm]
Circuit diagram
IN OUT
286±3.0
150
2-ø5.5 x 7
2-ø5.5
6-6M
270
255±1.0
240
120
90±1.0
(18)(13)
Label
1
2
3
4
5
6
Option
part No.
9ROWDJH
specifications
for driver
Manufacturer's
part No.
Applicable
driver (frame)
Manufacturer
DV0P3410 3-phase 200V
683+/(5%
F-frame Okaya Electric Ind.
7. Options
Noise Filter
5HFRPPHQGHGFRPSRQHQWV
Part No.
9ROWDJH
specifications
for driver
Current rating
(A)
Applicable driver
(frame)
Manufacturer
RTHN-5010
3-phase 200V
10 A, B, C-frame
TDK-Lambda Corp.RTHN-5030 30 D-frame
RTHN-5050 50 E, F-frame
[RTHN-5010]
195±1
210±2
50±2
6-M4
M4
4.5
10±1
18.5±1
78±1
4.5±1
95±2
18.5±1
[RTHN-5030]
225±1
240±2
55±2
6-M4
M4
4.5
10±1
18.5±1
85±1
4.5±1
105±2
18.5±1
[RTHN-5050]
280±1
300±2
68±2
6-M5
M4
5.5
12.5±1
21±1
102±1
5.5±1
128±2
21±1
Remarks
 6HOHFWDQRLVHÀOWHURIFDSDFLW\WKDWH[FHHGVWKHFDSDFLW\RIWKHSRZHUVRXUFHDOVR
check for load condition).
 )RUGHWDLOHGVSHFLÀFDWLRQRIWKHÀOWHUFRQWDFWWKHPDQXIDFWXUHU
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com