2-25
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
: High voltage
Ground
(earth)
Ground
terminal
Short bar (DB3-DB4)
0RWRUFDEOH6KLHOGZLUH
;WR;DUHXVHGIRUWKHVHFRQGDU\
circuit. To connect these terminals to
the primary power supply (particularly,
24 VDC power supply for brake),
insulation is required.
Do not connect these terminals to the
same power supply.
Brake cable
DC Power supply
for brake DC24V
(to be supplied
by customer)
Junction cable for encoder
U
-phase
V
-phase
:
-phase
Charge lamp (LED)
Do not make displacement, wiring or
inspection while the LED is lit - cause
of electric shock.
PC (to be supplied
by customer)
6HWXSVXSSRUWVRIWZDUH´3$1$7(50µ
Please download from our web site.
&RQQHFWLRQWR3&3$1$7(50
&RQQHFWLRQWR5656
or host controller
&RQQHFWLRQWR6DIHW\E\SDVVSOXJ
&RQQHFWLRQWRencoder
&RQQHFWLRQWRfeedback scale
&RQQHFWLRQWRKRVWFRQWUROOHU
:LULQJWR&RQQHFWRU; P.
:LULQJWR&RQQHFWRU; P. 2- 5 5
:LULQJWR&RQQHFWRU; P.2-54
:LULQJWR&RQQHFWRU; P.2-53
:LULQJWR&RQQHFWRU; P.2-51
:LULQJWR&RQQHFWRU; P.2-51
0RQLWRURXWSXW
:LULQJWR&RQQHFWRU; P.2-60
P.2-26
&RQQHFWLRQWRPRWRUGULYLQJ
SKDVHDQGJURXQG
5HPDUNV
NC
NC
NC
L2C
L1C
NC
NC
NC
DB3
DB2
DB1
DB4
L1
L2
L3
B1
B2
NC
U
V
W
X1
X2
X3
X4
X5
X6
CHARGE
2. 6\VWHP&RQÀJXUDWLRQDQG:LULQJ
Overall Wiring (G-frame, 200 V type)
Note
Related page
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
• The figure above shows connections on velocity, position, torque and full-closed mode driver.
• Only for position control type is not provided.
• P.2-26 "Wiring of the Main Circuit (G-frame, 200 V type)"
• P.2-48 "Specifications of Motor connector"