69
AK110 Programming Screen Navigation, ORP Cycle Time (2 of 2)
Setpoint Overfeed Screen
Use the keypad to enter the daily
maximum accumulated feed time.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Overfeed Screen
Enter new value
Current: 03:00:00
03:00:00
v-Cancel ^
Enter
Enter
ORP Cycle, Setpoint Overfeed
ORP Cycle, Overfeed
Use the keypad to enter the runtime
allowed to reach 5% of setpoint.
Disables relay if setpoint is not met.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Enter new value
Current: 00:00:00
00:00:00
v-Cancel ^
From ORP Cycle Time (1 of 2)
ManualTime 00:02:00
Proportional% 5
On If ORP< 700
Off If pH> 7.95
Off If pH< 0.00
Off if RLY On 1
Cycle Time 00:02:00
On Limit 00:00:30
Off if Sw1 Off-YES
Off if Sw2 On –NO
SetOvrfeed 00:00:00<
Overfeed 03:00:00
ManualTime 00:02:00
Proportional% 5
On If ORP< 700
Off If pH> 7.95
Off If pH< 0.00
Off if RLY On 1
Cycle Time 00:02:00
On Limit 00:00:30
Off if Sw1 Off-YES
Off if Sw2 On –NO
SetOvrfeed 00:00:00
Overfeed 03:00:00<
ORP Cycle, Independent of SW2
Enter
ORP Cycle, Feed Off if SW2 is On
Press the [Enter] key to make the
sanitizer feed dependent or
independent of the status of switch 2
(SW2.)
ManualTime 00:02:00
Proportional% 5
On If ORP< 700
Off If pH> 7.95
Off If pH< 0.00
Off if RLY On 1
Cycle Time 00:02:00
On Limit 00:00:30
Off if Sw1 Off-YES
Off if Sw2 On –NO <
SetOvrfeed 00:00:00
Overfeed 03:00:00
ManualTime 00:02:00
Proportional% 5
On If ORP< 700
Off If pH> 7.95
Off If pH< 0.00
Off if RLY On 1
Cycle Time 00:02:00
On Limit 00:00:30
Off if Sw1 Off-YES
Off if Sw2 On –YES <
SetOvrfeed 00:00:00
Overfeed 03:00:00
ORP Cycle , Feed Off if SW1 is Off
Enter
ORP Cycle, Independent of SW1
Press the [Enter] key to make the
sanitizer feed dependent or
independent of the status of the flow
switch SW1.
ManualTime 00:02:00
Proportional% 5
On If ORP< 700
Off If pH> 7.95
Off If pH< 0.00
Off if RLY On 1
Cycle Time 00:02:00
On Limit 00:00:30
Off if Sw1 Off-YES <
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 03:00:00
ManualTime 00:02:00
Proportional% 5
On If ORP< 700
Off If pH> 7.95
Off If pH< 0.00
Off if RLY On 1
Cycle Time 00:02:00
On Limit 00:00:30
Off if Sw1 Off-NO <
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 03:00:00
Use the keypad to enter the cycle
duration, including both sanitizer
feed ON time and feed OFF time.
Press the [Enter] key to confirm or
the down arrow key to cancel.
Cycle Time Screen
Enter new value
Current: 00:02:00
00:02:00
v-Cancel ^
Use the keypad to enter the
maximum sanitizer feed duration.
Press the [Enter] key to confirm or
the down arrow key to cancel.
On Limit Screen
Enter new value
Current: 00:00:30
00:00:30
v-Cancel ^
Enter
Enter
ORP Cycle, Cycle Time
ORP Cycle, On Limit
ManualTime 00:02:00
Proportional% 5
On If ORP< 700
Off If pH> 7.95
Off If pH< 0.00
Off if RLY On 1
Cycle Time 00:02:00<
On Limit 00:00:30
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 03:00:00
ManualTime 00:02:00
Proportional% 5
On If ORP< 700
Off If pH> 7.95
Off If pH< 0.00
Off if RLY On 1
Cycle Time 00:02:00
On Limit 00:00:30<
Off if Sw1 Off-YES
Off if Sw2 On -NO
SetOvrfeed 00:00:00
Overfeed 03:00:00
AK110 Programming Screen Navigation, ORP Cycle Time, Rev 3 22 Aug 2008