TROUBLESHOOTING
Problem Possible Cause Corrective Action
Pump failure.
Pump will not prime - Air leak, too
much air.
Pump will not prime - Not enough
water.
Pump stainer gasket is clogged.
Pump strainer gasket is defective.
Check suction piping and valve glands on any suction gate
valves. Secure lid on pump strainer pot and be sure lid gasket is
in place. Check water level to be sure skimmer is not drawing air.
Be sure the suction lines, pump, strainer, and pump volute are
full of water. Be sure valve on suction line is working and open
(some systems do not have valves). Check water level to make
sure water is available through skimmer.
Clean pump strainer pot.
Replace gasket.
Reduced capacity and/
or head.
Air pockets or leaks in suction line.
Clogged impeller.
Pump strainer clogged.
Check suction piping and valve glands on any suction gate
valves. Secure lid on pump strainer pot and be sure lid gasket
is in place. Check water level to be sure skimmer is not
drawing air.
Turn o electrical power to the pump.
Disassemble (see page 20, ‘Pump Disassembly’)
Clean debris from impeller. If debris cannot be removed,
complete the following steps:
1. Remove left hand thread anti-spin bolt and o-ring.
2. Remove, clean, and reinstall impeller.
Reassemble (see page 21, ‘Pump Reassembly’)
Clean suction trap.
Pump fails to start.
Mains Voltage is not present
Pump shaft is locked
Pump shaft is damaged
1. Replace fuse, reset breaker/GFCI.
2. Tighten mains wire connections.
Check if the pump can be rotated by hand and remove any
blockage.
Replace pump.
Pump runs then stops.
Over temperature FAULT
Over current FAULT
Check that back of pump is free from dirt and debris. Use
compressed air to clean.
Pump will automatically restart after one (1) minute.
Diagnosing certain symptoms may require close interaction with, or in close proximity to,
components that are energized with electricity. Contact with electr icity can cause death, personal
injury, or property damage. When trouble shooting the pump, diagnostics involving electricity
should be cared for by a licensed professional.
English

Table of Contents

Other manuals for Pentair SuperFlo VS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair SuperFlo VS and is the answer not in the manual?

Pentair SuperFlo VS Specifications

General IconGeneral
Horsepower1.5 HP
ControlDigital
Energy EfficiencyENERGY STAR Certified
Warranty1-year limited warranty
Motor TypePermanent Magnet Motor
Maximum Head50 feet
Speed RangeVariable Speed
TypeVariable Speed
Union Connection2-inch
Port Size2-inch