28
Programming Configuring using the ICS Switchbox
Other general settings
These functions are available with ICS config. files released after October 15, 2010 and apply for the
majority of seat types.
All the function settings specified below are initiated by the following process:
1.
Switch off the wheelchair by pressing the start key on the R-net control panel.
2. You must press and hold a combination of buttons on the ICS Switchbox while powering up
the wheelchair. Press and hold buttons 2, 7 and 8 on the ICS Switchbox while powering up the
wheelchair by pressing the start key on the control panel.
The ICS Switchbox buttons can be released once all its LEDs light up green. You can now access page
1 of the Set-up settings.
LEDs 7 and 8 alternately flash green, which indicates that Set-up mode has been activated and that
page 1 in the Set-up menu has been selected.
It is now possible to choose a set-up function. The buttons used have a toggle function, i.e. each time
you press one it switches between the two settings.
If you are on page 1 in the Set-up menu and want
to access page 2, press button 4.
If you are on page 2 in the Set-up menu and want
to access page 3, press button 4.
If you are on page 2 or 3 in the Set-up menu and
want to return to previous page, press button 8.
Page 1 is visible when LEDs 7 and 8 alternately
flash green.
Page 2 is visible when LED 7 flashes green.
Page 3 is visible when LED 8 flashes green.
Settings on page 1 in the Set-up menu
Blocking actuator movement during operation.
To adjust the degree of actuator movement during operation of the wheelchair, press button 1.
When LED 1 lights up green, all actuators are blocked during operation.
When LED 1 lights up red, all actuators are unblocked during operation.
Low back installed.
To specify whether a low back has been installed on the wheelchair, press button 5. This limits the
maximum back angle.
When LED 2 lights up green, a low back is installed.
When LED 2 lights up red, no low back is installed.
Adapter for -5° tilt installed.
To specify whether this adapter has been installed or not, use button 2.
When LED 3 lights up green, the adapter for -5° tilt is installed.
When LED 3 lights up red, no adapter for -5° tilt is installed.