Care and Maintenance
12 - 2
54-024
12.02 Machine oil level
Check oil level before each use.
● The oil level must be between the
markings in the inspection glass.
● If required refill oil through hole 1.
Only use oil with a mean
viscosity of 22.0 mm²/s at 40º C
and a density of 0.865 g/cm³ at
15º C!.
We recommend PFAFF
sewing machine oil. Order-No.
280-1-120 144.
Fig. 12 - 02
12.03 Cleaning/lubricating the top feed joints
● Once a week or after the machine has
stood still for longer periods, clean the
points marked in the illustration with the
special cleaner, part no. 99-137 468-91.
● Afterwards lubricate these points with the
special lubricant, part no. 99-137 467-91
(wipe off surplus lubricant with a cloth).
Fig. 12 - 03
1