23
Installation and commissioning
● Connect the machine to the compressed
air system. A pressure of 6 bar should
be displayed on the manometer. If neces-
sary, set this value, see Chapter 12.02
Checking / adjusting the air pressure.
8.02 Commissioning
● Examine the machine, in particular the electric leads, for any damage.
● Clean the machine thoroughly, also see Chapter 12 Maintenance.
● Connect the machine to the electrical network and have specialists examine, whether the
machine can be operated with the available voltage and whether it is properly connected.
Do not operate the machine if there is any discrepancy!
The machine may only be connected to an earthed socket!
134-010
0
+
-
1
0.2 0.8
0.4 0.6
Fig. 8 - 02
1
The air must be completely oil-
free and dry.
The compressed air quality
influences the service life of the
heating cartridge in the air
heater. If the air is very damp,
a compressed air cold drier with
preliminary filter and secondary
fine filter must be installed in
front of the heat-sealing
machine