Adjustment
98
13.13.02 Temperature control error
Error number Discription
0 No error
1 Thermoelement 1 disconnection (HW-alarm-bit)
2 Control circuit not reacting
3 Temperature window (alarm) exceeded
4 No temperature increase despite of controller full scale (heating
cartridge defective or thermo element slipped from holder)
Display Description
ERROR: 319 Read error in MDAT-fi le
ERROR: 330
#Prog. No. #Zone No.
Program. speed > max. gear-controlled speed
ERROR: 331
#Prog. No.. #Zone No.
Programmed roller pressure > roller pressure
limit
ERROR: 332
#Prog. No.. #Zone No.
Speed and differential outside permissible values
ERROR: 340 # Zone No. Selected temperature too high
ERROR: 341 # Zone No. Air volume does not match nozzle type
ERROR: 342 # Zone No. Programmed sealing off not plausible
ERROR: 343 # Zone No. Programmed output (OUT) not plausible
ERROR: 344
# Program No.
Program not for this machine, nozzle/wedge
PROGRAM XX
NOT IN MEMORY
Program XX does not exist
ERROR: 401 Text fi le cannot be opened
ERROR: 402 Error in read text fi le
ERROR: 501 Error when opening fi le "pikto.hex" or "vorlagen.
hex" disconnect error
ERROR: 502 No ACK from control panel Disconnect error