Mixing pump G 4 X smart Overview - Operation and service
Cleaning the machine after work
2021-08-12 53
43.2 Secure against restarting
DANGER!
Danger to life from unauthorised restarting!
When working with the machine there is the risk that
the energy supply is switched on without
authorisation. This poses a danger to life for the
persons in danger area.
Switch off all power supplies before starting any
work and secure against restarting.
If protective covers have been removed for
cleaning purposes, they must be properly put back
again without fail after completion.
43.3 Cleaning the G 4 X
ATTENTION!
Water can enter sensitive machine parts!
Before cleaning the machine cover all openings in
which no water must enter for safety and functional
reasons (e.g. electric motors and control cabinets).
NOTE!
Do not direct the water jet on electrical parts, such as
gear motor or control cabinet.
43.4 Decouple mortar hose
Fig. 78: Mortar pressure to "0" bar.
1. Check at the mortar pressure gauge (1) if the mortar pressure is
at "0 bar".
DANGER!
Overpressure on the machine!
When opening machine parts they can open in an
uncontrolled manner and injure the operator.
Open machine only when the pressure is at "0
bar".
2. Loosen the cam lever (2) and decouple the mortar hose from
the mortar pressure gauge.
1
2