Measures in case of risk of frost
2021-08-12 59
46 Measures in case of risk of frost
ATTENTION!
Damage by frost!
Water that expands inside the machine during frost
can cause severe damage.
Therefore:
The following steps are to be carried out if the
machine stands still in case of risk of frost.
1 2
Fig. 92: Disconnect water supply
1. Close external water supply.
2. Disconnect the water hose (1) from the mixing tube.
3. Open draining cocks (2).
4. Open the water draining cock at the booster pump AV 1000.
Fig. 93: Strainer
5. Open and empty strainer.
46.1 Blow dry water fitting
Fig. 94: Dry water fitting
1. Connect water/air hose (1) with EWO and Geka coupling to the
water inlet (2) and to the outlet of the air fitting (3).
3
1
2