Mixing pump G 4 X smart Overview - Operation and service
Maintenance
66 2021-08-12
47.6.1
47.7 Adjust locking lever
1 2 3
Fig. 107: Eccentric bushing
NOTE!
By tur
ning the eccentric bushing (1) with the special
wrench (2)
in the tool
bag, the locking lever (3) can be
adjusted.
Loosen locking lever and turn eccentric bushing.
Close the locking lever and check if this action closes the
mixing tube again tightly.
47.8 Measures after effected maintenance
1. After finishing the maintenance works and prior to switching on
the machine, the following steps have to be carried out:
2. Check all previously loosened screw connections for secure fit.
3. Check if all previously removed safety systems and covers are
properly reinstalled.