Mixing pump G 4 X smart Overview - Operation and service
Maintenance
60 2021-08-12
Fig. 95: Dry water fitting
2. Turn main switch (4) to position "I".
3. Turn the star wheel (5) of the booster pump to position “0”.
46.2 Switch on air compressor
Fig. 96: Air compressor
1. Switch on the air compressor using the black switch (1).
2. Press the water supply button (pos. 6
fig. 95).
3. The water is now blown out of the fitting using compressed air
(for approx. 15 seconds).
4. Switch off the compressor at the red switch (1).
5. Turn main switch to position "0".
47 Maintenance
47.1 Safety
Personnel The maintenance works described here can be carried out by
the operator, unless marked otherwise.
Some maintenance work must only be carried out by specially
trained technical personnel or exclusively by the manufacturer.
Work on the electrical system must, in principle, be carried out
only by electricians.
Basic information
WARNING!
Risk of injury due to improperly carried out
maintenance work!
Improper maintenance can lead to severe injuries
or considerable property damage.
Therefore:
Ensure order and safety at the assembly site!
Loose, stacked components or components lying
about can cause accidents.
If components were removed, ensure proper
assembly, put back all fastening elements and
observe torque indications for screws.
1
4
5
6